Lay Z Spa Pump Heater For Vegas Miami tested and works properly as it should if you require any further information don?t hesitate to ask. I will courier this 3 - 5 working days via Hermes. The Lay-Z-Spa is not designed to operate with water temperatures exceeding 40ºC (104ºF). Unplug the pump and plug it back in once the water temperature has reached 38ºC (100ºF) or lower. IMPORTANT: Before you restart the pump, press the reset button.
There are only a few things that can go wrong with a spa pump. The inlet or outline line could become clogged outlet. The pump may leak around the base, or it may not operate at all. Any malfunctions other than these should probably be attended to by a trained professional, but these problems may have simple solutions. Step 1: Diagnose the ProblemIf your spa pump is leaking or or not flowing, examine it to find out what the problem may be.
If the intake is not working, the problem might be a clog. Repair it by simply removing the obstruction. Similarly, there is no need to remove the pump if problems are caused by objects that have become jammed in the jets. Step 2: Disconnect the PowerDo not perform any repairs on a hot tub pump until after the power has been disconnected.
This may involve a circuit breaker or a separate box mounted near the pump. Never work on water-moving devices while the electricity is running. Step 3: Remove the PumpRemove the spa circulation pump.
In most cases, this removal entails removing 4 to 8 bolts, but some models use other mounting methods. If you have trouble getting a bolt to turn, spray it with WD-40 or some other penetrating fluid, and allow the bolts to set for 5 to 10 minutes. Step 4: Clean ConnectorsClean the connectors thoroughly. Check any washers or gaskets used in the connectors or the pump mounts. Replace worn or damaged gaskets.
For a tighter seal, place a drop of oil on the washer or filter, and rub it into the entire surface.Inspect the pump for any foreign objects that have gotten lodged inside it. Even a small piece of plastic could cause the pump to jam, rendering it ineffective.
Step 5: Remount the PumpCarefully mount the pump back on the motor. If there is a gasket between the pieces, make sure it is properly in place before installing the bolts.
To install bolts, snug each one in a clockwise direction, and then start over and tighten each bolt down, in the same pattern. This helps to give you an even, consistent seal. Step 6: Restore Power and TestRestore the power to the motor and turn it on. If all has gone well, the leaks will be fixed. If you still have leaks, repeat the process.
If leaks are still present after a second attempt, you may need the services of a plumber. Step 7: Motor ProblemsIf the motor does not operate, your problem is not with the pump.
Unless you have moderate experience in household electrical procedures, you should leave repairing a faulty electric motor to a trained technician. You can even remove the motor and take it to a repair center.
.#54124E, #54130E, #54149E, #54155E, #54157E 110-120V60Hz, 12A at 20ºC TO THE STORE QUESTIONS? MISSING PARTS?
Lay Z Spa Error 02
Tel: 1-855-838-3888 service@bestwaycorp.us For FAQ, Manuals, Videos Or Spare Parts, Please Visit www.bestwaycorp.com Owner’s Manual Website: www.bestwaycorp.com Visit Bestway YouTube channel S-S-004676 S-S-004676/21x28.5cm/54124E,54130E,54149E,54155E,54157E/美国规Salu SPA说明书/JS-YF-2016-B-05547/英.CONTENTS 1. Maintenance.Filter Cartridge Maintenance 2.
Specifications.Water Maintenance Air-Valve Adjustment 3. Installation.Draining the Spa Selected Location Cleaning the Spa GFCI Test Spa Repair Assembly SaluSpa Storage 4. Pump Operation.6. Troubleshooting.Control Panel Alarms 7.CAUTION: To avoid damage to the pump, the spa must never be operated unless the spa is filled with water. CAUTION: Immediately leave spa if the user feels uncomfortable or sleepy.
NOTE: Please examine equipment before use. Notify Bestway at the customer service address ®.NOTE:The warning label must be posted near your spa in a readable position during using your spa. Take out the warning label from the accessory kit. Carefully peel the warning label. Affix the warning label. To order the warning label, please contact your local Coleman After Sales Service. To reach 104°F (40°C), the heating duration required is base on the starting water temperature and ambient temperature, the data below is purely for reference.SPECIFICATIONS FOR SaluSpa™ MIAMI (#54124E) AirJet Capacity: 2-4 Adults Massaging Turbo 6.5A Increased Heat Approximately Blower: Rate: 2-3ºF/h (1.0-1.5ºC/h) Water Capacity (80%): 177 gal.
(669 L) Heat Element: 11.3A at 68ºF(20ºC) Power Rate: 110-120V AC, 12A at 68ºF(20ºC) Inflated Size: 71 in.Part N. Part Code Description 54130TASS17 Pool liner P4B080USASS17 Spa Heater P5602Q17 Top Leatheroid Cover 54129GASS17 Inflatable Cover P6930 Inflation Hose P6653 Filter Set 58426S17 Chemical Floater 58321(H)S15 Ground Mat F6H189ASS15 Wrench P6575 Stoppers P61199 Pressure Gauge P6611 Cover Adapter A P6H971 Inflation Valve F6414ASS.Part N. Description Part Code Pool liner 54149TASS16 Spa Heater P4H063USASS17 Top Leatheroid Cover P5H284GASS17 Liner Leatheroid Cover P5H514TASS17 Inflatable Cover 54148GASS16 Inflation Hose P6931 Filter Set P6653 Chemical Floater 58426S17 Stoppers P6575 Ground Mat 58321(H)S15 Screw Valve F4A024ASS Cover Adapter A P6611 LED Strip P61718.SaluSpa™ SPECIFICATIONS FOR Siena AirJet (#54157E ) Capacity: 2 Adults Massaging Turbo Increased Heat Approximately 6.5A Blower: Rate: 3-4ºF/h (1.5-2.0ºC/h) Water Capacity (80%): 134 gal. (509 L) Heat Element: 11.3A at 68ºF(20ºC) Power Rate: 110-120V AC, 12A at 68ºF(20ºC) Inflated Size: 98’’.INSTALLATION Selected Location IMPORTANT: Because of the combined weight of the SaluSpa, water, and users, it is extremely important that the base where the SaluSpa is installed is smooth, flat, level and capable of uniformly supporting the weight for the entire time the SaluSpa is installed (not on the carpet or other similar material).MIAMI AirJet (#54124E) 3 seconds to unlock. To stop inflation. Inflate for 5 min.
Inflate for 2 min. PALM SPRINGS AirJet (#54130E) 3 seconds to unlock. 0.08Bar(1.2PSI) Inflate for 5 min. To stop inflation.
Inflate for 2 min. PARIS AirJet (#54149E) 3 seconds to unlock.Inflate for 2 min. HAWAII AirJet (#54155E) Inflate for 5 min. 0.08Bar(1.2PSI) 3 seconds to unlock. Inflate for 2 min. To stop inflation. SIENA AirJet (#54157E) Inflate for 5 min.
Lay Z Spa Error 33 Free
0.08Bar(1.2PSI) 3 seconds to unlock. Inflate for 2 min.
To stop inflation. S-S-004676 S-S-004676/21x28.5cm/54124E,54130E,54149E,54155E,54157E/美国规Salu SPA说明书/JS-YF-2016-B-05547/英.2. The water flow sensors are broken. Contact your local Bestway Aftersales service point to get instructions. After starting or during the 1. You forgot to remove the 3 stopper caps from inside 1.
Remove the 3 stopper caps before heating. Refer to Assembly section in the functions of filtering or/and the pool.CAUTION: YOU MUST ENSURE THE PUMP IS UNPLUGGED BEFORE BEGINNING SPA MAINTENANCE TO AVOID RISK OF INJURY OR DEATH. Filter Cartridge Maintenance NOTE: To ensure your spa water stays clean, check and clean your filter cartridges every day follow the steps below.
58323 Filter Cartridge P6653.Draining the Spa NOTE: Drawings for illustration purpose only. May not reflect actual product. Not to scale. P6611 NOTE: Lift up the spa when there is only a little water left. Damages to the handles are not covered under the warranty. NOTE: Dry the spa pool.Check and make sure the seals are placed correctly inside the pump adapters. If the seals are missing or not installed correctly, please contact your local Bestway After Sales Service Center for instructions.
If the seals are correctly in place, reconnect the pump to the SPA and hand-tighten the adapters.30 days for hoses, fitting and accessory included in the package from the original date of purchase To enact a warranty claim, this form must be completed and supplied with a copy of your receipt/purchase to your local Bestway After Sales Center.